CHSYQ - STATGUARD CONDUCTIVE FLOOR FINISH

  • MSDS: CHSYQ
  • Manufacturer: CHARLESWATER PRODUCTS INC
  • Product Name: STATGUARD CONDUCTIVE FLOOR FINISH
  • National Stock Number: 6850-00N029143
Product Identification

Product ID:STATGUARD CONDUCTIVE FLOOR FINISH
MSDS Date:05/26/1992
FSC:6850
NIIN:00N029143
Status Code:A
MSDS Number: CHSYQ

Responsible Party
CHARLESWATER PRODUCTS INC
93 BORDER STREET
WEST MEWTON, MA 02165
US

Emergency Phone: 800-255-3924

Info Phone: 617-965-8370

Cage: 63070

Contractor
CHARLESWATER PRODUCTS,INC.
WEST MEWTON, MA 02165-2013 US

Telephone: 617-964-8370

Cage: 63070

Ingredients

MODIFIED ACRYLIC POLYMER (NONHAZARDOUS)

Fraction By Weight: 35-40%

OSHA PEL N/K

ACGIH TLV: N/K


WAX EMULSION; (EMULSIFIED WAXES) (NONHAZARDOUS)

Fraction By Weight: 5-10%

OSHA PEL N/K

ACGIH TLV: N/K


WATER; (H*2O) (NONHAZARDOUS)

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: BALANCE

OSHA PEL N/K

ACGIH TLV: N/K


DIPROPYLENE GLYCOL MONOMETHYL ETHER

CAS: 34590-94-8

RTECS: JM1575000

Fraction By Weight: 3-4%

OSHA PEL 100 PPM, S

ACGIH TLV: 100 PPM;150 STEL, S


DIETHYLENE GLYCOL MONOETHYL ETHER

CAS: 111-90-0

RTECS: KK8750000

Fraction By Weight: 2-3%

OSHA PEL N/K

ACGIH TLV: N/K


AMMONIA (SARA 302/313) (CERCLA)

CAS: 7664-41-7

RTECS: BO0875000

Fraction By Weight: 0.01%MAX

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM;35 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION:MINOR IRRITATION.
SKIN/EYES:SLIGHT IRRITATION. INGESTION:NONE KNOWN.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:OVEREXPOSURE MAY AGGRAVATE ASTHMA.

First Aid

First Aid:INHAL:MOVE SUBJECT TO FRESH AIR. SKIN:WASH W/SOAP & WATER.
INGEST:DRINK SEVERAL GLASSES OF WATER (DO NOT INDUCE VOMITING).
CONTACT MD. EYES:FLUSH FOR AT LEAST 15 MINUTES.

Fire Fighting

Extinguishing Media:FOAM, CO*2, DRY CHEMICAL & WATER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. DIKE & CONTAIN SPILL
W/INERT MATERIAL (E.G., SAND, EARTH). KEEP SPILLS & CLEANING
RUNOFFS OUT OF MUNICIPAL SEWERS & OPEN BODIES OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORAGE TEMPERATURE: MAX - 49C/120F;
MIN 1C/34F.
Other Precautions:KEEP FROM FREEZING - PRODUCT MAY COAGULATE.

Exposure Controls

Respiratory Protection:WEAR NIOSH APPROVED RESPIRATOR WHERE EXPOSURE
LIMITS ARE EXCEEDED.
Ventilation:LOCAL EXHAUST:MECHANICAL AT POINT OF CONTAMINATION
RELEASES.
Protective Gloves:IMPERVIOUS/NEOPRENE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH SKIN W/SOAP & WATER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:>200F,>93C
Spec Gravity:>1 (H*2O=1)
pH:8-9
Solubility in Water:COMPLETE
Appearance and Odor:OPAQUE, TAN LIQUID W/WAX OR AMMONIACAL ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NOT APPLICABLE.
Stability Condition to Avoid:TEMPERATURES ABOVE 49C/120F & BELOW
1C/34F.
Hazardous Decomposition Products:NONE KNOWN.

Disposal

Waste Disposal Methods:COAGULATE EMULSION BY STEPWISE OF FERRIC
CHLORIDE & LIME. REMOVE CLEAR SUPERNATENT LIQUID & FLUSH TO
CHEMICAL SEWER. INCINERATE SOLIDS & CONTAMINATED DIKING MATERIAL
ACCORDING TO LOCAL, STATE & FEDERA L REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.